Description
Detect silane (SiH₄) with the NextTeq NX209 detector tube, offering a dual measuring range of 1–50 ppm (single pump stroke) or 0.5–25 ppm (two pump strokes) with a detectable limit of 0.3 ppm. This tube reacts with silane to shift from yellow to red, with results read directly off the printed scale calibrated for one pump stroke. With a 1-year shelf life when stored refrigerated, it's a precise solution for monitoring this pyrophoric gas used in semiconductor manufacturing.